EcoFit MV replaces legacy breakers with modern technology—enhancing reliability and safety while keeping original infrastructure intact.

Asset Vulnerability

Aging Breakers.
Rising Risks.

Legacy MV breakers lose speed and hide wear. Panels stay in service, but reliability drops—leading to coordination hazards and safety risks during switching.

Worn mechanisms and timing drift

Aging breakers lose speed, leading to dangerous tripping errors.

Rising contact resistance

Joint overheating goes unseen, building thermal stress over time.

No visibility into breaker health

Zero real-time diagnostics on mechanical fatigue or gas pressure.

Arc-flash vulnerability

Weak interlocks and old designs compromise operator safety.

Long outage windows for repairs

Frequent maintenance stalls production and raises repair costs.

Worn mechanisms and timing drift

Aging breakers lose speed, leading to dangerous tripping errors.

Rising contact resistance

Joint overheating goes unseen, building thermal stress over time.

No visibility into breaker health

Zero real-time diagnostics on mechanical fatigue or gas pressure.

Arc-flash vulnerability

Weak interlocks and old designs compromise operator safety.

Long outage windows for repairs

Frequent maintenance stalls production and raises repair costs.

Modernization Engineering

Meet EcoFit MV — Retrofits That Keep Panels Alive For Another Decade

EcoFit MV replaces aging breakers with new EvoPact HVX and EasyPact EXE units—engineered to fit straight into existing cubicles using type-tested kits. No busbar touch. No cable revisions. No civil work. Just fast modernization with full IEC 62271-100 compliance, smooth draw-out operation, and defined interlocks. Add digital sensors and old panels become connected, predictable, and ready for high-duty operation.

EcoFit Modernization

Tested For
Real MV Duty

Type-tested kits. OEM breakers. Full IEC conformity.

Upgrade PathHWX → EvoPact HVX
Voltage RangeUp to 12 kV
CurrentUp to 3150 A
Breaking PowerUp to 40 kA, 3 s
TechVacuum technology
Endurance10,000 operations
Speed25–45 ms opening time
HandlingDraw-out, closed-door option
Retrofit Hardware
Upgrade PathEvolis → EasyPact EXE
Voltage RangeUp to 17.5 kV
Current630 – 2500 A
Fault Duty31.5 kA, 3 s
Impulse95 kV surge withstand
Mech Life10,000 operations
LogicStandard & fast operating
Widths570 / 700 / 900 mm kits

Faster Upgrades.
Safer Switching.

BENEFIT_01

Safer operation

Closed-door switching, tested interlocks, and mechanisms built for modern duty cycles.

BENEFIT_02

Higher reliability

New vacuum breakers with OEM-tested speed, endurance, and fault-handling.

BENEFIT_03

Digital-ready panels

Add TH110 sensors and EcoStruxure connectivity for condition monitoring.

BENEFIT_04

Sustainable modernization

Replace only what’s needed. Recycle removed breakers. Extend panel life by years.

BENEFIT_05

Minimal shutdown

Retrofit in hours, not days. Keep busbars, cables, and the full switchboard intact.

BENEFIT_06

Predictable maintenance

A clear spares path for the new breakers, mechanisms, and digital devices.

BENEFIT_01

Safer operation

Closed-door switching, tested interlocks, and mechanisms built for modern duty cycles.

BENEFIT_02

Higher reliability

New vacuum breakers with OEM-tested speed, endurance, and fault-handling.

BENEFIT_03

Digital-ready panels

Add TH110 sensors and EcoStruxure connectivity for condition monitoring.

BENEFIT_04

Sustainable modernization

Replace only what’s needed. Recycle removed breakers. Extend panel life by years.

BENEFIT_05

Minimal shutdown

Retrofit in hours, not days. Keep busbars, cables, and the full switchboard intact.

BENEFIT_06

Predictable maintenance

A clear spares path for the new breakers, mechanisms, and digital devices.

Where EcoFit Keeps
The Grid Alive

01

Process Facilities

Continuous-duty industrial processing lines.

02

Infrastructure Networks

High-traffic transport and municipal hubs.

03

Petrochemical Sites

Hazardous oil, gas, and chemical terminals.

04

Data Centers

Uptime-critical mission-critical operations.

05

Industrial MV Rooms

Retrofitting for compact factory substations.

06

Utility Substations

Aging primary distribution grid modernization.

07

Manufacturing Plants

High-cycle automotive and metal foundries.

Built For
Tough Environments

01

Utilities

02

Oil & Gas

03

Cement & Metals

04

Manufacturing

05

Infra & Transport

06

Mission-critical facilities

Modernization Without Disruption.