Industrial Resilience • Sepam Series 60

Protection That Stands Firm When The Grid Gets Tough

Sepam Series 60 brings rugged, multifunctional protection for feeders, motors, transformers, generators, and capacitors — backed by modular I/O, deep diagnostics, and industrial-grade endurance.

Site Vulnerability

Harsh Networks
Break Weak Protection.

Old relays fail under heat, dust, and vibration — losing CT/VT supervision and leaving operators blind during disturbances. The result? Slow clearing and zero clarity.

Weak EF detection

Standard units miss early earth faults in ungrounded or high-impedance systems.

No harsh-site resilience

Relays fail prematurely under high heat, humidity, and constant vibration.

Missing CT/VT checks

Zero real-time supervision of measurement circuits leads to blind operational errors.

Shallow fault records

Lack of COMTRADE data makes it impossible to analyze fast-moving disturbances.

Rigid schemes

Fixed logic prevents relays from adapting to evolving industrial bay configurations.

Meet Sepam Series 60
Built For Realities.

ANSI-grade protection wrapped in a tough, conformal-coated design. Covering everything from overcurrent to synchro-check. With modular I/O and IEC 61850 networking, it becomes the core of any substation bay.

Front Panel / Advanced UMI
Sepam 60 Interface

Industrial Strength
Flexible Integration.

Built for tough sites. Designed for modern grids. Rugged boards that resist humidity, dust, and vibration.

01

Deep diagnostics

CT/VT supervision, breaker condition, and trip circuit health monitored in real time.

02

Powerful event insight

COMTRADE disturbance records and detailed SOE logs capture every millisecond.

03

Modular expansion

I/O, RTD inputs, and analog outputs scale as your substation requirements grow.

04

Digital-ready integration

IEC 61850 Level 2, GOOSE messaging, and redundancy with ACE850.

Industrial strength. Intelligent protection.

Built for tough sites. Designed for modern grids.

SupervisionCT/VT and Trip circuit real-time supervision
ProtocolsIEC 61850 Level 2 (ACE850), Modbus RTU/TCP, DNP3
ConnectivityIEC 60870-5-103 and Fiber optic options
Time SyncIRIG-B & SNTP millisecond synchronization
Power Supply24–250 V DC & 100–240 V AC options
Endurance–25°C to +70°C operation with Conformal coating
InputsCT inputs: 1 A / 5 A and LPCT support
RangeWide voltage input range (220 V to 220 kV)
I/O HardwareExpandable digital I/O with MES120 modules
MountingDIN rail or panel-mount modular design
Sepam 60 Technical Features
OvercurrentPhase/earth, directional & non-directional
Earth FaultSensitive Earth Fault (SEF) & REF protection
Power LogicDirectional overpower and underpower
ThermalAdvanced Thermal overload monitoring
Machine LogicDifferential protection (model-dependent)
SupervisionMotor start & operation supervision
Grid ControlSynchro-check and Recloser control
FailsafeBreaker failure (50BF) protection
ANSI GradeRugged multifunctional bay protection
ClarityFast COMTRADE records and deep diagnostics
One Platform. Many Bays.

Where Sepam 60 Brings Clarity & Control

Dependable protection even under electrical stress and industrial heat.

SEP_APP_01

Industrial Switchboards

Rugged protection for LV/MV industrial power distribution hubs.

Extreme Site Duty
SEP_APP_02

Harsh Environments

Conformal-coated protection for sites with heat, dust, and vibration.

Extreme Site Duty
SEP_APP_03

Transformer Bays

Comprehensive differential and REF logic for critical power assets.

Extreme Site Duty
SEP_APP_04

Feeder Protection

Reliable overcurrent and earth fault logic for distribution networks.

Extreme Site Duty
SEP_APP_05

Motor & RTD

Advanced thermal monitoring and supervision for heavy industrial motors.

Extreme Site Duty
SEP_APP_06

Capacitor Banks

Specialized protection functions designed for voltage and VAR control.

Extreme Site Duty
SEP_APP_01

Industrial Switchboards

Rugged protection for LV/MV industrial power distribution hubs.

Extreme Site Duty
SEP_APP_02

Harsh Environments

Conformal-coated protection for sites with heat, dust, and vibration.

Extreme Site Duty
SEP_APP_03

Transformer Bays

Comprehensive differential and REF logic for critical power assets.

Extreme Site Duty
SEP_APP_04

Feeder Protection

Reliable overcurrent and earth fault logic for distribution networks.

Extreme Site Duty
SEP_APP_05

Motor & RTD

Advanced thermal monitoring and supervision for heavy industrial motors.

Extreme Site Duty
SEP_APP_06

Capacitor Banks

Specialized protection functions designed for voltage and VAR control.

Extreme Site Duty
SEP_APP_01

Industrial Switchboards

Rugged protection for LV/MV industrial power distribution hubs.

Extreme Site Duty
SEP_APP_02

Harsh Environments

Conformal-coated protection for sites with heat, dust, and vibration.

Extreme Site Duty
SEP_APP_03

Transformer Bays

Comprehensive differential and REF logic for critical power assets.

Extreme Site Duty
SEP_APP_04

Feeder Protection

Reliable overcurrent and earth fault logic for distribution networks.

Extreme Site Duty
SEP_APP_05

Motor & RTD

Advanced thermal monitoring and supervision for heavy industrial motors.

Extreme Site Duty
SEP_APP_06

Capacitor Banks

Specialized protection functions designed for voltage and VAR control.

Extreme Site Duty

Engineered For The World’s Toughest Operations

Trusted wherever reliability is non-negotiable

Utilities

Oil & Gas

Mining & Metals

Cement

Chemical & Process

Data Centers

Utilities
Utilities

Critical Networks Support

Ideal for harsh industrial sites and critical utility substations. Even under heat, dust, vibration, and electrical stress.

Relay Testing, Programming & Configuration
Commissioning support for harsh environments
Protection coordination audits
Support Site

Rugged. Reliable.
Firm.