Acts Before
Damage Begins.
PowerLogic™ A1 and A3 devices provide light-speed arc flash detection for LV and MV enclosures, saving assets and lives.
Arc flash hazards
demand light-speed response.
Arc flash faults cause severe damage in milliseconds. Traditional systems react too slowly, leaving critical installations exposed.
Delayed arc detection
Standard relays react too slowly to catch the initial flare before pressure builds.
Higher equipment damage risk
Sub-cycle detection is required to prevent catastrophic copper vapor explosions.
Limited safety coverage
Traditional protection often leaves personnel exposed during manual operations.
Complex retrofit challenges
Legacy cubicles often lack the space or wiring for integrated safety systems.
PowerLogic™ A1 & A3
Arc-Flash Protection, Instantly
Advanced arc-flash protection devices for low- and medium-voltage switchgear, using optical detection to identify arc faults and trigger ultra-fast breaker tripping. A1 operates as a standalone unit, while A3 enables scalable zone-based protection systems.

Act Faster.
Save Assets.
Arc-fault containment that stops fires before they start, DRAMATICALLY reducing incident energy.
Improved personnel safety
Dramatically reduces incident energy levels by tripping in milliseconds.
Rapid optical detection
Uses light-speed optical sensors to catch the arc flare instantly.
Simple configuration
Easy setup using physical dip-switches or intuitive software tools.
Flexible deployment
Use A1 as a standalone guard or A3 for scalable multi-zone systems.
Safety-Critical
Performance
Designed for sub-cycle interception and modular scalability.

Where A1 & A3 Make The Difference
Optical detection that catch the flare before the pressure wave builds.
Selective Zones
A3 ensures only the faulted zone isolates, maintaining facility uptime.
Instant Trip
Dedicated hardware for sub-cycle breaker operation during faults.
Retrofit Ready
Modular design allows for easy installation in legacy MV/LV switchgear.
Scalable Safety
Connect multiple A3 units for comprehensive plant-wide coverage.
Visual Logic
Front-facing LED indicators for rapid fault source location.
Dual Detection
Combined light and current sensing to prevent nuisance tripping.
Selective Zones
A3 ensures only the faulted zone isolates, maintaining facility uptime.
Instant Trip
Dedicated hardware for sub-cycle breaker operation during faults.
Retrofit Ready
Modular design allows for easy installation in legacy MV/LV switchgear.
Scalable Safety
Connect multiple A3 units for comprehensive plant-wide coverage.
Visual Logic
Front-facing LED indicators for rapid fault source location.
Dual Detection
Combined light and current sensing to prevent nuisance tripping.
Selective Zones
A3 ensures only the faulted zone isolates, maintaining facility uptime.
Instant Trip
Dedicated hardware for sub-cycle breaker operation during faults.
Retrofit Ready
Modular design allows for easy installation in legacy MV/LV switchgear.
Scalable Safety
Connect multiple A3 units for comprehensive plant-wide coverage.
Visual Logic
Front-facing LED indicators for rapid fault source location.
Dual Detection
Combined light and current sensing to prevent nuisance tripping.
Built For Power Reliability
Trusted across utility and industrial sectors