VAMTECH- Voltage Ampere Measurement Technology.

Logo
Transformer Standard • MiCOM P64x

Transformer Protection That Thinks Faster Than Faults.

MiCOM P64x delivers high-speed differential, REF, and thermal protection built for multi-winding zones where precision is absolute.

Winding Integrity

A Fault Doesn't Wait.
Your Protection Shouldn't Either.

Older relays misjudge inrush and ignore overfluxing. That means false trips, long outages and high-value transformers pushed beyond safe physical limits.

Slow fault isolation

Delayed response to internal faults risks catastrophic core and stator damage.

Poor inrush restraint

Standard units misread energisation, causing nuisance trips and substation downtime.

Weak earth-fault sensitivity

Missed low-level internal ground faults can escalate into transformer fires.

No overfluxing defense

Inability to restrain during V/Hz surges pushes cores beyond safe magnetic limits.

Limited event insights

Generic relays lack the recording depth required for EHV-grade grid forensics.

Meet MiCOM P64x
— Transformer-grade protection, perfected.

The P64x family (P642 / P643 / P645) brings phase-segregated differential protection with transformer-specific logic. Fits simple two-winding units and complex EHV autotransformers alike with modular 40–80TE hardware.

Clinical Logic / Winding Selective
MiCOM P64x Slider 1

Protection Tuned To
Transformer Physics.

From overfluxing to winding faults — P64x adapts to real physics and transformer behavior.

01WINDING_LOGIC

REF for the smallest faults

Low- and high-impedance options detect internal earth faults early.

02WINDING_LOGIC

Thermal expertise built in

IEEE-based thermal modelling protects winding hot-spots and top-oil levels.

03WINDING_LOGIC

Overfluxing control

Multi-stage V/Hz protection keeps magnetic stress in check during grid swings.

04WINDING_LOGIC

Directional backup

Four fully configurable stages for selective internal and external fault isolation.

05WINDING_LOGIC

Smart supervision everywhere

Continuous VT/CT monitoring, breaker failure, and negative sequence diagnostics.

06WINDING_LOGIC

High-speed differential logic

Phase-segregated and stable even during CT saturation and heavy inrush.

Designed For Winding Selectivity & Accuracy

Modular Build. High-end sensing. Overfluxing defense.

INPUTSCT inputs 1A / 5A | Up to 16 digital inputs
SENSINGRTD inputs for up to 10 PT100 sensors
REFTransformer REF inputs (low & high Z)
OUTPUTSUp to 24 outputs with high-break DC options
PROTOCOLSIEC 61850, DNP3, MODBUS, IEC 60870-5-103
NETWORKEthernet with PRP/HSR/RSTP & Process Bus (9-2LE)
HARDWARE40TE / 60TE / 80TE case options | IP52 front
SUPPLY24–250 VDC / 100–240 VAC range
MiCOM P64x Technical Stage
DIFFERENTIALPhase-segregated transformer differential (87T)
EARTH FAULTRestricted Earth Fault (REF) - low/high impedance
BACKUP4-stage Directional Overcurrent IDMT / DT
UNBALANCENegative phase sequence current protection
FLUXINGMulti-stage Overfluxing (VHz) control logic
GRID SUITEUnder/over voltage and frequency protection
FAILSAFEBreaker failure (50BF) & VT/CT supervision
AUTOMATIONFully programmable PSL logic & IRIG-B Sync
Integrated Substation Scope

Where MiCOM P64x Delivers Clarity

Protection that fits every transformer topology from simple units to EHV autotransformers.

P64X_APP_01

EHV Transformer Bays

High-speed differential logic for transmission-level grid assets.

Transformer Core
P64X_APP_02

Two-Winding Units

Stable and selective protection for standard Distribution Transformers.

Transformer Core
P64X_APP_03

Autotransformers

Specialized compensation logic for complex autotransformer configurations.

Transformer Core
P64X_APP_04

Ring Bus Stations

Integrated bay control and protection for mesh station topologies.

Transformer Core
P64X_APP_05

Industrial Substations

Rugged protection for manufacturing hubs with continuous load switching.

Transformer Core
P64X_APP_06

Three-Winding Units

Coordinated three-end differential logic for multi-winding assets.

Transformer Core
P64X_APP_01

EHV Transformer Bays

High-speed differential logic for transmission-level grid assets.

Transformer Core
P64X_APP_02

Two-Winding Units

Stable and selective protection for standard Distribution Transformers.

Transformer Core
P64X_APP_03

Autotransformers

Specialized compensation logic for complex autotransformer configurations.

Transformer Core
P64X_APP_04

Ring Bus Stations

Integrated bay control and protection for mesh station topologies.

Transformer Core
P64X_APP_05

Industrial Substations

Rugged protection for manufacturing hubs with continuous load switching.

Transformer Core
P64X_APP_06

Three-Winding Units

Coordinated three-end differential logic for multi-winding assets.

Transformer Core

Transformer Protection Set Up
Exactly Right

We configure, test and verify P64x settings for every winding, tap and fault scenario

Transformer SAT

Switchyard Complete Testing,
Commissioning & Maintenance

Technical Implementation

  • Circuit Breaker Overhauling & Testing
  • HT & LT Panel Testing & Maintenance
  • Relay Testing, Programming & Configuration

Made For Transformers.
Built For Critical Networks.

Ideal for high-duty networks with continuous load and complex switching.

Transmission utilities

Distribution networks

Heavy industries

Refineries & process plants

Generation switchyards

Transmission utilities
Transmission utilities
Supporting Systems For Complete Transformer Schemes

Complementary Units.

Compatible protection, monitoring, and communication products designed to operate alongside MiCOM P64x.

MiCOM P14x

MiCOM Platform Member

MiCOM P14x

MiCOM P24x

MiCOM Platform Member

MiCOM P24x

MiCOM P341 & MiCOM P922G

MiCOM Platform Member

MiCOM P341 & MiCOM P922G

MiCOM P34x

MiCOM Platform Member

MiCOM P34x

Detect.
Trip.
Protect.