VAMTECH- Voltage Ampere Measurement Technology.

Logo
Transmission Logic • MiCOM P43x

Built For Lines That Demand Accuracy.

MiCOM P43x delivers adaptive distance protection with six-zone coverage and SOTF readiness for modern transmission networks.

Line Vulnerability

Faults escalate fast.
Weak protection makes them worse.

Old relays miss swings, misjudge high-resistance faults, and slow down during voltage dips—leading to mis-ops and blind zones.

Limited distance zones

Inadequate zone coverage leads to protection blind spots on long transmission lines.

Slow fault capture

Delayed clearing during voltage dips causes severe grid instability and stress.

Poor event visibility

Lack of high-res recording makes root-cause analysis after a trip impossible.

Missed weak-infeed faults

Traditional logic fails to detect high-resistance faults in weak networks.

Meet MiCOM P43x
Smarter Detection. Faster Isolation.

MiCOM P43x becomes the anchor protection for transmission lines, cables, and mixed feeders. Six-zone adaptive coverage ensures every line stays visible and protected.

Adaptive Logic / 6 Zones
MiCOM P43x

Engineered For
Protection Depth.

Modular hardware. Sharp measurement. Strong communication across modern transmission networks.

01
DATA_POINT

Distance multi-zone

Fast six-zone coverage with adaptive logic for mixed feeders.

02
DATA_POINT

PSB & Out-of-step

Identifies stable power swings from actual faults to prevent false trips.

03
DATA_POINT

SOTF Readiness

Switch-on-to-fault logic ensures safety during manual closing operations.

04
DATA_POINT

PRP/HSR Redundancy

High-availability seamless redundancy for zero-packet-loss communication.

05
DATA_POINT

Disturbance Insight

COMTRADE and precise event logs for deep post-fault forensics.

06
DATA_POINT

Arc Flash Safety

Optional integrated high-speed arc detection for personnel security.

Sharp Measurement. Reliable Logic.

Modular Build. High-end protection. Redundant Ethernet.

Hardware & Comms
DesignModular case options (40TE/84TE) & IP52 front
SupplyWide-range auxiliary supply (AC/DC)
Endurance–25°C to +55°C with High EMC immunity
MountingFlexible mounting: Panel, Rack, or Wall
HardwareMultiple binary I/O with Expansion modules
SamplingTrue RMS sampling and Harmonics analysis
PortsEthernet, Fiber, and RS485 Native support
ProtocolsIEC 61850 Ed.1/Ed.2, Modbus, DNP3, IEC-103
RedundancyHSR & PRP Parallel Redundancy protocols
P43x Blueprint
Protection Logic
SyncTime sync via SNTP and IRIG-B
DataCOMTRADE Disturbance records & Event logs
ZonesDistance protection multi-zone (6 zones)
CurrentOvercurrent DT/IDMT & Ground fault REF
MachineDirectional power, voltage & Frequency
VoltageUndervoltage and Overvoltage elements
ControlSOTF, PSB, Out-of-step and Breaker failure
GridInrush blocking and Cold load pickup
High-Accuracy Deployment

Where P43x Sets the Standard

Precision distance logic for transmission lines and railway power grids.

P43X_APP_01

Transmission lines

Six-zone adaptive logic for overhead HV lines and underground cables.

Transmission Core
P43X_APP_02

Industrial Feeder

Robust handling of weak networks and high-resistance faults.

Transmission Core
P43X_APP_03

Rail Electrification

Specific distance logic tuned for electrified railway power grids.

Transmission Core
P43X_APP_04

Generation Bay

Safe power export for large solar, wind, and thermal generation plants.

Transmission Core
P43X_APP_05

Digital Substation

Redundant Ethernet HSR/PRP support for modernized grid architectures.

Transmission Core
P43X_APP_06

Smart Isolation

Fast fault clearance (25-45ms) to maintain total network stability.

Transmission Core
P43X_APP_01

Transmission lines

Six-zone adaptive logic for overhead HV lines and underground cables.

Transmission Core
P43X_APP_02

Industrial Feeder

Robust handling of weak networks and high-resistance faults.

Transmission Core
P43X_APP_03

Rail Electrification

Specific distance logic tuned for electrified railway power grids.

Transmission Core
P43X_APP_04

Generation Bay

Safe power export for large solar, wind, and thermal generation plants.

Transmission Core
P43X_APP_05

Digital Substation

Redundant Ethernet HSR/PRP support for modernized grid architectures.

Transmission Core
P43X_APP_06

Smart Isolation

Fast fault clearance (25-45ms) to maintain total network stability.

Transmission Core

Distance Protection Tuned To
Your Network

From zone settings to logic — we configure P43x with precision

Engineering Testing

Relay Testing, Programming &
Configuration

Relay Testing, Programming & Configuration

  • Coordination Studies
  • Zone 6 Logic Calibration
  • Site Verification

Built For
Power Reliability

Trusted across transmission & industrial sectors

Utilities & Grid

Transmission Lines

Industrial Plants

Rail Infrastructure

Utilities & Grid
Utilities & Grid
Integrated MiCOM Ecosystem

Complementary Protection.

Engineering and maintenance services for selective fault isolation.

MiCOM P13x

Platform Member

MiCOM P13x

MiCOM P63x

Platform Member

MiCOM P63x

MiCOM P53x

Platform Member

MiCOM P53x

MiCOM P138

Platform Member

MiCOM P138

Detect. Isolate.