VAMTECH- Voltage Ampere Measurement Technology.

Logo
Railway Excellence • MiCOM P436 & P438

Built For Catenary Protection.

Advanced digital distance and overcurrent protection engineered specifically for railway traction networks and substations.

Route Integrity

In rail networks,
seconds feel like miles.

Outdated relays struggle with multi-voltage grids, high inrush, and dead-tank transformers. Slow trips ripple downtime across the entire transit route.

Delayed Traction Trips

Delayed clearing in catenary lines risks wide-area route shutdowns.

Multi-voltage instability

Legacy gear fails to adapt to diverse railway traction voltage bands.

Unsafe control switching

Unreliable local/remote switching increases risk during rail maintenance.

Catenary blind spots

Traditional relays miss high-resistance faults in weak traction networks.

Meet MiCOM P436 & P438
— Built for catenary protection.

Digital distance and overcurrent protection relays for railway catenary feeders. P436 covers 16.7 Hz networks, while P438 handles 25/50/60 Hz systems. Both deliver advanced interlocking, bay control, and deep diagnostics in modular Px3x hardware built to thrive in demanding traction substations.

Traction Hardware / Modular Px3x
MiCOM P436/P438 Slider 1

Protection Shaped
For Traction.

From synchronism check to distance logic, P436/P438 secures rail power backbones.

01TRACTION_LOGIC

Distance protection multi-zone

Fast multi-zone coverage with adaptive logic for mixed traction feeders.

02TRACTION_LOGIC

SOTF & PSB Readiness

Switch-on-to-fault safety and power swing blocking for grid stability.

03TRACTION_LOGIC

Integrated switchgear control

Operate breakers and feeders directly from the high-res relay HMI.

04TRACTION_LOGIC

Auto-reclose restores fast

Intelligently keeps catenary systems energised after transient faults.

05TRACTION_LOGIC

Voltage & Frequency stability

Strict over/under elements for railway-specific grid compliance.

06TRACTION_LOGIC

Detailed rail recording

COMTRADE records and event logs for deep post-fault rail forensics.

Designed for Railway-Grade Resilience

Traction frequency support with high-speed isolation

ARCHITECTURE3 Current + 2 Voltage inputs tuned for rail
BINARY I/OExpandable 12 Binary I/O mapping capability
FREQUENCYNative 16.7, 25, 50, and 60 Hz support
HARDWAREModular case (40TE/84TE) & IP52 front
ENDURANCE–25°C to +55°C with high EMC immunity
P436/P438 Technical
PROTOCOLIEC 61850 Ed1/Ed2, Modbus, DNP3, IEC-103
REDUNDANCYHSR & PRP Parallel Redundant protocols
TIME SYNCPrecision IRIG-B & SNTP synchronization
LOGICSynchronism check (25) & CB failure (50BF)
DATADeep Event & Fault Disturbance recording
Substation Deployment

Where P436 & P438 Lead the Network

Core protection for 16.7Hz metro networks and global railway electrification hubs.

CAT_APP_01

Catenary Feeders

Selective high-speed trips designed for overhead railway lines.

Catenary Security
CAT_APP_02

Traction Substation

Primary protection hub for HV/MV railway grid interconnections.

Catenary Security
CAT_APP_03

Electrified Metro

High-density bay protection for urban transit power backbones.

Catenary Security
CAT_APP_04

Generation Yards

Safe power export from plant generation to railway grids.

Catenary Security
CAT_APP_05

Infrastructure Hubs

Securing station and terminal power with multi-frequency logic.

Catenary Security
CAT_APP_06

Industrial Rail

Handling high inrush and multi-voltage loads in industrial bays.

Catenary Security
CAT_APP_01

Catenary Feeders

Selective high-speed trips designed for overhead railway lines.

Catenary Security
CAT_APP_02

Traction Substation

Primary protection hub for HV/MV railway grid interconnections.

Catenary Security
CAT_APP_03

Electrified Metro

High-density bay protection for urban transit power backbones.

Catenary Security
CAT_APP_04

Generation Yards

Safe power export from plant generation to railway grids.

Catenary Security
CAT_APP_05

Infrastructure Hubs

Securing station and terminal power with multi-frequency logic.

Catenary Security
CAT_APP_06

Industrial Rail

Handling high inrush and multi-voltage loads in industrial bays.

Catenary Security

Rail Protection Tuned To
Your Network

Multi-frequency tuning and catenary stability assessment

Rail Testing

Relay Testing, Programming &
Configuration

Traction Substation Tuning

  • 16.7Hz Metro Logic Tuning
  • Distance Coordination Studies
  • Catenary SOTF Validation

Built For
Power Reliability

Trusted across utility and traction sectors

Railways & Metro

Transport Infrastructure

Industrial Substations

Utility Grid

Railways & Metro
Integrated MiCOM Ecosystem

Complementary Rail Units.

Engineering and maintenance services for selective traction isolation.

MiCOM P138

Platform Member

MiCOM P138

MiCOM P63x

Platform Member

MiCOM P63x

MiCOM P43x

Platform Member

MiCOM P43x

MiCOM P53x

Platform Member

MiCOM P53x

Rugged. Precise. Resilient.