VAMTECH- Voltage Ampere Measurement Technology.

Logo
Generator Core • MiCOM P34x

Advanced Generator Safeguarding Built to Respond Instantly.

MiCOM P34x protects generators and generator-transformer systems with high-speed differential protection, intelligent backup logic, and accurate synchronism supervision.

Plant Risk

In Generation,
One Wrong Second Can Drop The Grid.

Legacy relays struggle with inrush, miss internal faults, and lack synchronism logic. A slowdown becomes an outage. An outage becomes a regional cascade.

Slow internal-fault clearing

Delayed response to winding faults can cause irreparable stator core damage.

Weak synchronism control

Inaccurate check-sync risks mechanical stress during breaker closing operations.

No redundancy options

Lack of PRP/HSR support creates single points of failure in digital links.

Poor breaker supervision

Missing trip-circuit and failure logic risks hardware damage during fault events.

Limited plant visibility

Generic relays lack the recording depth needed for fast post-fault restoration.

Meet MiCOM P34x
— Generator-Grade Protection With Total Control.

Hardened differential protection, synchronism checks and complete scheme logic into one modular platform (P342–P391). Optimised for GT units and complex plant bays, it blends fast 87G detection and deep recording logic for modern substations.

Hardened Core / 100MVA+ Ready
MiCOM P34x Slider 1

Protection Built Around
How Generators Behave.

From internal faults to synchronism checks — every risk handled.

01MACHINE_LOGIC

Instant internal-fault detection

Biased differential 87G logic with inrush and overfluxing restraint.

02MACHINE_LOGIC

Multi-layer backup protection

Phase, earth-fault, and sensitive EF with directional and frequency options.

03MACHINE_LOGIC

Stability under every condition

Voltage, frequency, and thermal monitoring that reacts before limits break.

04MACHINE_LOGIC

Breaker health assurance

Breaker failure, condition supervision, and trip-circuit logic built directly in.

05MACHINE_LOGIC

Flexible scheme logic

PSL for interlocking, intertripping and plant-specific sequence mapping.

06MACHINE_LOGIC

Smarter synchronism

Advanced native check-sync (25) for safe, seamless breaker closing.

07MACHINE_LOGIC

Deep event visibility

Waveforms, SOE, and fault locators for quicker plant-side restoration.

Built For Precision. Proven In Harsh Plant Environments.

Every module meets generator-grade performance standards

HARDWAREUp to 32 binary inputs & 32 Configurable outputs
SENSING1A / 5A CT support & Voltage inputs for sensing
ANALOGRTD/analog inputs supported via CLIO expansion board
PROTOCOLSIEC 61850 Ed.1/Ed.2, Modbus, Courier, DNP3
NETWORKRedundant Ethernet (PRP/HSR/RSTP) & Serial RS485
TIME SYNCPrecision IRIG-B & SNTP Synchronization
TELEPORTInterMiCOM high-speed cross-site signaling support
CASING40 / 80 TE modular case options with IP52 front
MiCOM P34x Technical Hub
DIFFERENTIAL87G biased differential with harmonic restraint
OVERCURRENTMulti-stage Phase & Earth fault protection
ADAPTIVESensitive EF / Neutral EF & Thermal overload (49)
SYNCAdvanced Check synchronization logic (25)
FAILSAFEBreaker failure (50BF) & Trip circuit supervision
AUTOMATIONIntertripping & interlocking via programmable PSL
GRIDComplete Voltage & frequency protection suite
DATASequence of events & waveform disturbance recording
Integrated Generation Scope

Where MiCOM P34x Leads the Plant

Any generator. Any topology. Any critical plant configuration.

P34X_APP_01

Generator Units

Fast 87G differential protection for high-value generating assets.

Generator Ready
P34X_APP_02

GT Units

Hardened protection for integrated Generator-Transformer topologies.

Generator Ready
P34X_APP_03

Captive Power

Reliable switching and backup for industrial captive power units.

Generator Ready
P34X_APP_04

Hydro & Thermal

Optimised logic for hydro, thermal and gas plant configurations.

Generator Ready
P34X_APP_05

Intertie Nodes

Synchronism-checked switching for critical substation intertie points.

Generator Ready
P34X_APP_06

Complex Bays

Complete scheme logic for complex station and bay automation.

Generator Ready
P34X_APP_01

Generator Units

Fast 87G differential protection for high-value generating assets.

Generator Ready
P34X_APP_02

GT Units

Hardened protection for integrated Generator-Transformer topologies.

Generator Ready
P34X_APP_03

Captive Power

Reliable switching and backup for industrial captive power units.

Generator Ready
P34X_APP_04

Hydro & Thermal

Optimised logic for hydro, thermal and gas plant configurations.

Generator Ready
P34X_APP_05

Intertie Nodes

Synchronism-checked switching for critical substation intertie points.

Generator Ready
P34X_APP_06

Complex Bays

Complete scheme logic for complex station and bay automation.

Generator Ready

Generator Protection Fine-Tuned
To Plant Logic

From 87G testing to synchronism settings — we configure P34x the way your generator runs.

Testing

Relay Testing, Programming &
Configuration

Technical Plant System Tuning

  • Differential sensitivity validation
  • Excitation/Sync logic calibration
  • Critical breaker-failure logic audits

Engineered For Generation.
Ready For Every Grid.

Perfect for high-value generating assets across power and industry.

Power generation plants

Captive power & industrial utilities

Independent power producers

Grid substations

Renewables with synchronous generators

Critical industrial generation processes

Power generation plants
Power generation plants
Integrated Solutions For Intertie Protection Schemes

Coordinated Systems.

Compatible protection, control and communication solutions designed to operate alongside MiCOM P34x.

MiCOM P54x

MiCOM Platform Member

MiCOM P54x

MiCOM P64x

MiCOM Platform Member

MiCOM P64x

MiCOM P740

MiCOM Platform Member

MiCOM P740

MiCOM P746

MiCOM Platform Member

MiCOM P746

Protect. Synchronize.
Generate.