Reliable Grid Link Security Built to Act Without Hesitation.
MiCOM P341 safeguards interconnecting lines and vital system interfacesusing rapid distance protection, advanced overcurrent functionality, and accurate frequency supervision.
Where Networks Connect,
Delay Can Lead to System Instability.
Traditional relays often fail to detect power swings accurately, struggle with intertie evaluation, and provide limited synchronism supervision. A single incorrect trip at a system boundary can disrupt stability across the entire network.
Slow fault detection
At the grid edge, a few milliseconds delay in clearing a fault triggers regional instability.
Weak swing stability
Standard relays misjudge power swings as faults, leading to unnecessary intertie trips.
Poor breaker oversight
Lack of condition monitoring and failure logic risks grid hardware damage during events.
Limited frequency logic
Relays cannot track ROCOF or vector shifts accurately during inter-regional transfers.
No redundancy paths
Single-point communication failure isolates the protection unit from central SCADA systems.
Meet MiCOM P341
— Interconnection protection with authority.
P341 blends multi-zone distance protection, PSL automation, and wide-frequency logic into one modular relay. Optimised for tie-lines and boundaries where stability, communication, and cyber security matter most.

Protection Tuned For
Interconnections.
From distance faults to frequency events — every boundary risk handled.
Swing & stability intelligence
Power swing blocking, out-of-step tripping, and vector-shift detection for stable operation.
Frequency-aware protection
ROCOF, under/over-frequency, and voltage-vector shift for reliable intertie management.
Breaker reliability built-in
Breaker failure, condition monitoring, and trip-circuit supervision ensure dependable clearing.
Flexible scheme logic
PSL for intertripping, permissive schemes, interlocking, and custom network logic mapping.
Deep line visibility
Dynamic line rating, disturbance waveforms, and thermal monitoring for informed grid operation.
Fast distance protection
Multi-zone distance elements with adaptive characteristics for precise boundary fault clearing.
Stronger backup layers
Phase, earth, sensitive earth, and restricted earth fault stages with inverse/definite curves.
Built For Precision. Proven On Demanding Networks.
Every module is designed for protection-critical performance.

Where MiCOM P341 Leads the Grid
Any interconnection. Any tie-line. Any complex protection boundary.
Interconnection Points
Primary protection for high-value inter-utility grid boundaries.
Tie-Line Feeders
Transmission and distribution tie-line management with distance logic.
Transformer Backup
High-density backup protection for critical substation transformers.
Busbar Interties
Synchronism and swing-checked busbar intertie schemes.
Boundary Points
Industrial and utility boundary points requiring frequency awareness.
Renewable Grids
Managing stability in hybrid grids with vector shift protection.
Interconnection Points
Primary protection for high-value inter-utility grid boundaries.
Tie-Line Feeders
Transmission and distribution tie-line management with distance logic.
Transformer Backup
High-density backup protection for critical substation transformers.
Busbar Interties
Synchronism and swing-checked busbar intertie schemes.
Boundary Points
Industrial and utility boundary points requiring frequency awareness.
Renewable Grids
Managing stability in hybrid grids with vector shift protection.
Interconnection Protection Tuned To
Your Network Logic
From distance settings to swing curves — we configure P341 the way your grid runs.
Relay Testing, Programming &
Configuration
Technical Assessment & Testing
- Intertie stability verification
- Power swing blocking tuning
- Boundary synchronism validation
Engineered For Grid Interconnections.
Ready For Every Network Type
Perfect for high-value, high-impact points across power and industry.
Utilities & Transmission
Grid Substations
Industrial Tie-Feeds
Independent Power Producers
Hybrid Renewable Grids
Critical Intertie Nodes
Complementary Units.
Compatible protection, control and communication equipment engineered to operate alongside MiCOM P341.

MiCOM Platform Member
MiCOM P746

MiCOM Platform Member
MiCOM P841

MiCOM Platform Member
MiCOM P14x

MiCOM Platform Member
