VAMTECH- Voltage Ampere Measurement Technology.

Logo
Feeder Standard • MiCOM P14x

Intelligent Line Defense That Stops Problems Before They Start.

MiCOM P14x offers high-speed, adaptable safeguardingfor both overhead transmission lines and underground cables — designed to operate reliably across different earthing arrangements, voltage ranges, and network layouts.

Grid Hesitation

Along Feeders,
Slow Response Leads to Bigger Problems.

Older relays often misread direction, struggle with compensated networks, and fall behind in complex grids — causing poor coordination and incorrect trips.

Weak directional logic

Relays misjudge fault direction, leading to nuisance trips in ring networks.

No SEF sensitivity

Standard relays miss low-level sensitive earth faults in compensated grids.

Slow cold-load handling

Inability to distinguish inrush from faults causes avoidable startup delays.

Inaccurate voltage restraint

Lower reach on distant faults during voltage dips compromises safety.

Poor event insight

Zero digital recording makes grid-forensics and root-cause analysis a guessing game.

Meet MiCOM P14x
— Feeder control done right.

A powerful feeder protection platform for MV and HV lines. It brings multi-stage, fully directional phase and earth-fault protection, high-sensitivity SEF, and deep recording logic — adapting to every feeder grounding practice and grid condition.

Universal Feeder / Modular Px40
MiCOM P14x Slider 1

Protection That Follows
Every Contour.

Direction, sensitivity and stability — engineered for complex line behaviour.

01CONTOUR_LOGIC

Three-layer earth-fault logic

Derived, measured and SEF — each with four stages for precision on every network type.

02CONTOUR_LOGIC

Voltage-dependent awareness

Voltage-controlled and restrained overcurrent boosts reach on distant faults safely.

03CONTOUR_LOGIC

REF for internal sensitivity

High- or low-impedance REF detects hidden faults missed by standard elements.

04CONTOUR_LOGIC

Negative-sequence intelligence

Detects unbalanced faults fast, even before current rises fully.

05CONTOUR_LOGIC

Thermal & overload security

Realistic multi-state models for cable, transformer and conductor protection.

06CONTOUR_LOGIC

Smarter feeder behaviour

Native cold load pickup and selective logic for accurate switching operations.

07CONTOUR_LOGIC

Six-stage phase protection

Shapeable directional IDMT or definite-time for any complex grading plan.

Built For Speed. Tuned For Selectivity.

Multi-stage logic, modular hardware and deep diagnostics

PROTOCOLIEC 61850 Ed.1/Ed.2 & K-Bus / RS-485 / Fibre
CONNECTIVITYModbus, DNP3, Courier & IEC 60870-5-103/101
REDUNDANCYRedundant Ethernet (PRP/HSR) & InterMiCOM
INPUTS1A/5A CT inputs & 100V-480V VT inputs
I/O RANGE8–32 Logic inputs and 7–32 Output relays
CASING40/60/80 TE case options with IP52 protection
ENDURANCE–25°C to +55°C & IEC 60255 Compliance
SYNCIRIG-B Time Synchronization precision
MiCOM P14x Technical Stage
PHASE6-stage phase overcurrent (50/51/67)
EARTH4-stage EF + SEF (50N/51N/67N/67W)
ADAPTIVEVoltage-dependent OC (51V) & REF (64)
UNBALANCENegative-sequence (46) & Broken conductor (46BC)
THERMALThermal overload (49) & Voltage suite (27/59)
FREQUENCYOver/under-frequency + df/dt (81)
CONTROLAuto-reclose (79) & Check sync (25) Logic
AUTOMATIONPower protection (32), dv/dt, & Cold load pickup
Integrated Feeder Scope

Where MiCOM P14x Makes The Difference

Flexible enough for every feeder — overhead, underground or hybrid.

P14X_APP_01

Overhead lines

Advanced directional protection for standard overhead line distribution.

Universal Feeder
P14X_APP_02

Underground cable

Thermal and sensitive fault detection logic for high-cap underground lines.

Universal Feeder
P14X_APP_03

Mixed line/cable

Hybrid logic handling different impedances and fault behaviors seamlessly.

Universal Feeder
P14X_APP_04

Petersen coil networks

High-sensitivity SEF logic for compensated and isolated grounding.

Universal Feeder
P14X_APP_05

Transmission Feeders

Precise coordination for complex HV/MV radial or ring grid topologies.

Universal Feeder
P14X_APP_06

Industrial Grids

Rock-solid reliability for refinery and heavy manufacturing power hubs.

Universal Feeder
P14X_APP_01

Overhead lines

Advanced directional protection for standard overhead line distribution.

Universal Feeder
P14X_APP_02

Underground cable

Thermal and sensitive fault detection logic for high-cap underground lines.

Universal Feeder
P14X_APP_03

Mixed line/cable

Hybrid logic handling different impedances and fault behaviors seamlessly.

Universal Feeder
P14X_APP_04

Petersen coil networks

High-sensitivity SEF logic for compensated and isolated grounding.

Universal Feeder
P14X_APP_05

Transmission Feeders

Precise coordination for complex HV/MV radial or ring grid topologies.

Universal Feeder
P14X_APP_06

Industrial Grids

Rock-solid reliability for refinery and heavy manufacturing power hubs.

Universal Feeder

Feeder Protection,
Engineered To Perform

We configure, test, integrate and retrofit every P14x to match your philosophy

Testing

Relay Testing, Programming &
Configuration

Technical System Implementation

  • Secondary coordination audits
  • Earth-fault sensitivity calibration
  • Retrofit bay modernization

Purpose-Built For Feeders.
Trusted Across Grids.

The P14x fits anywhere lines need accurate direction and fast clearing.

Utilities & DISCOMs

Transmission operators

Industrial distribution

Transport and infrastructure

Oil, gas & process plants

Utilities & DISCOMs
Utilities & DISCOMs
Integrated Systems For Complete Protection

Complementary Solutions.

Compatible protection, control and communication solutions designed to work alongside MiCOM P14x.

MiCOM P34x

MiCOM Platform Member

MiCOM P34x

MiCOM P44x

MiCOM Platform Member

MiCOM P44x

MiCOM P54x

MiCOM Platform Member

MiCOM P54x

MiCOM P64x

MiCOM Platform Member

MiCOM P64x

Detect. Trip.
Restore.